Agrichemical product classification Agrichemical emergency phone numbers
Emergency response video Technical bulletins Protocols

 
 

 
H: Bulk Storage and Handling

No. Protocol
Full
Compliance
Score
Actual
Score
H1 The materials used for the installation, storage, containment and transfer of bulk liquid and dry products are compatible with the products to be stored.
Observations:
20

H1
Each warehouse owner shall obtain documentation from the manufacturer/supplier which identifies storage and handling materials which are compatible with the products being stored.

No. Protocol
Full
Compliance
Score
Actual
Score
H2 This installation is positioned such that vehicles servicing the bulk installation have adequate space to manoeuvre safely.
Observations:
10

H2
Inspect the bulk site for sufficient room for vehicles to manoeuvre safely.

No. Protocol
Full
Compliance
Score
Actual
Score
H3 The bulk installation is designed such that during transfer of products a containment pad/drip pan is utilized to prevent spills from contaminating soil and groundwater.
Observations:

20

H3
Inspect the site where transfer of product takes place. Discuss with the warehouse operator how spill prevention is maintained during transfer. Some operators may use drip pans which are also acceptable.

No. Protocol
Full
Compliance
Score
Actual
Score
H4 The outside bulk installation is:
a) fenced (either the site or localized around the tanks).
b) well lit (either the site or localized around the tanks).
Observations:
10

10

H4
A bulk installation not housed in a building must be fenced. If the site is fenced to provide security during non working hours, this is also acceptable. Lighting must be provided to enable safe operation at night.

No. Protocol
Full
Compliance
Score
Actual
Score
H5 The bulk storage tanks for dry products are diked with concrete or steel and the dike is not less than 10 cm. in height.
Observations:

mandatory

H5
The auditor will verify that the dry storage tanks are diked with concrete or steel and the dike is not less than 10 cm. in height.

No. Protocol
Full
Compliance
Score
Actual
Score
H6 The dike for liquid tanks is designed in such a way as to prevent spouting.
Observations:


20

H6
Inspect the liquid bulk tank containment drawings against the actual installation to ensure that if spouting occurs, spilled product is contained within the bulk storage diked area.

No. Protocol
Full
Compliance
Score
Actual
Score
H7 The dike for liquid tank storage is designed in such a way as to hold 110% of the largest tank plus the volume taken up by the other tanks inside the dike in the event of a rupture.
Observations:


mandatory

H7
Inspect the containment drawings and/or calculations used to determine the appropriate size of the containment. Measure the containment volume to verify. See sample calculations attached [Appendix E]. No other products, totes, tools etc of any kind can be stored within the diked area.

No. Protocol
Full
Compliance
Score
Actual
Score
H8 Each bulk liquid tank was fitted with a conservation vent and each bulk tank for dry products was fitted with a rupture disk.
Observations:


10

H8
Inspect each tank to ensure that it is vented (vacuum/pressure) and that foreign objects cannot enter through the vent. Some products require a conservation vent to ensure that moist air cannot enter the tank and thus avoid skimming of the product. Look for this feature in the supplier's operations manual. Tanks for bulk dry products must have a rupture disk.

No. Protocol
Full
Compliance
Score
Actual
Score
H9 Each bulk tank has, as a minimum, one visible label as to its contents which conforms with P.C.P. Regulations and the NFC where required.
Observations:


10

H9
Inspect to ensure that each tank has a P.C.P. label. If required, NFC label must be applied.

No. Protocol
Full
Compliance
Score
Actual
Score
H10 Each tank has a secured inspection port/manhole.
Observations:

10

H10
Inspect each tank for a secure and/or lockable inspection port or manhole.

No. Protocol
Full
Compliance
Score
Actual
Score
H11 The discharge line and sampling port from the tanks are locked when not in use.
Observations:

mandatory

H11
The discharge line and sampling port from the tank must be locked when not in use.

No. Protocol
Full
Compliance
Score
Actual
Score
H12 A check list covering all aspects of maintenance and operation for the bulk station is used. The preventative maintenance program and last check list were reviewed for:
a) yearly and weekly inspection checklists
b) bulk delivery checklist
Observations:

10

10

H12
The required check list (or similar) for yearly inspections, weekly inspection during operations, and a bulk delivery check list, will be inspected for completeness. If not used in a timely manner, non compliance would be indicated.

No. Protocol
Full
Compliance
Score
Actual
Score
H13 Storage facility has developed and implemented written operating procedures for:
a) decanting bulk liquid products
b) receiving bulk liquid products
c) removing and disposal of precipitation
Observations:


10
10
10


H13
The auditor shall verify the procedures by examining the written documents.

No. Protocol
Full
Compliance
Score
Actual
Score
H14 There are no underground storage tanks for agrichemicals on this site.
Observations:

mandatory

H14
The auditor will request confirmation from the facility owner that there are no underground storage tanks of agrichemical products.

H. Bulk Storage and Handling
Full
Compliance
Score
Actual
Score
    Scored Items
170
    There are 4 mandatories in this section